FIA Reagent
SAA/CRP Combo FIA
SAA/CRP Combo FIA
Product name:
Serum amyloid A/C-reactive protein Combo test kit
Packing specification:
20 tests/box; Quality control product for SAA: 2×0.5mL (optional) ;Quality control product for CRP: 2×0.5mL (optional)
Intended use:
This kits uses immunofluorescence double antibody sandwich assay to quantitatively detect the content of serum amyloid A (SAA) and C-reactive protein (CRP) in human serum, plasma or whole blood.
Major components:
1 reagent strip per aluminum bag for one person test use, 1 piece of ID card, 20 pieces of diluent, quality control products.
Storage conditions and expiration period:
The reagent should be stored at 4~30℃ and is valid for 18 months. After the aluminum bag of the test reagent is opened, it is effective within 2 hours. It is recommended to use it within 1 hour.
Quality control products should be stored at 2~8℃ and is valid for 18 months. After uncap the bottle, it is recommended to use up within 1 month.
Applicable instrument:
iRaTe 300, iRaTe 1600 dry fluorescence immunoassay analyzer from Aucheer.
PCT FIA
PCT FIA
Product name:
Procalcitonin test kit
Packing specification:
20 tests/box; Quality control product: 2×1.5mL (optional)
Intended use:
This kits uses immunofluorescence double antibody sandwich assay to quantitatively detect the content of Procalcitonin (PCT) in human serum, plasma or whole blood.
Major components:
1 reagent strip per aluminum bag for one person test use, 1 piece of ID card, quality control products.
Storage conditions and expiration period:
The reagent should be stored at 4~30℃ and is valid for 18 months. After the aluminum bag of the test reagent is opened, it is effective within 2 hours. It is recommended to use it within 1 hour.
Quality control products should be stored at 2~8℃ and is valid for 18 months. After uncap the bottle, it is recommended to use up within 1 month.
Applicable instrument:
iRaTe 300, iRaTe 1600 dry fluorescence immunoassay analyzer from Aucheer.
NT-proBNP FIA
NT-proBNP FIA
Product name:
N-terminal pro brain natriuretic peptide test kit
Packing specification:
20 tests/box; Quality control product: 2×1.5mL (optional)
Intended use:
This kits uses immunofluorescence double antibody sandwich assay to quantitatively detect the content of N-terminal pro brain natriuretic peptide (NT-proBNP) in human serum, plasma or whole blood.
Major components:
1 reagent strip per aluminum bag for one person test use, 1 piece of ID card, quality control products.
Storage conditions and expiration period:
The reagent should be stored at 4~30℃ and is valid for 18 months. After the aluminum bag of the test reagent is opened, it is effective within 2 hours. It is recommended to use it within 1 hour.
Quality control products should be stored at 2~8℃ and is valid for 18 months. After uncap the bottle, it is recommended to use up within 1 month.
Applicable instrument:
iRaTe 300, iRaTe 1600 dry fluorescence immunoassay analyzer from Aucheer.
NGAL FIA
NGAL FIA
Product name:
Neutrophil Gelatinase-associated Lipocalin test kit
Packing specification:
20 tests/box; Quality control product: 2×1.5mL (optional)
Intended use:
This kits uses immunofluorescence double antibody sandwich assay to quantitatively detect the content of Neutrophil Gelatinase-associated Lipocalin (NGAL) in human urine.
Major components:
1 reagent strip per aluminum bag for one person test use, 1 piece of ID card, quality control products.
Storage conditions and expiration period:
The reagent should be stored at 4~30℃ and is valid for 18 months. After the aluminum bag of the test reagent is opened, it is effective within 2 hours. It is recommended to use it within 1 hour.
Quality control products should be stored at 2~8℃ and is valid for 18 months. After uncap the bottle, it is recommended to use up within 1 month.
Applicable instrument:
iRaTe 300, iRaTe 1600 dry fluorescence immunoassay analyzer from Aucheer.
MPO FIA
MPO FIA
Product name:
Myeloperoxidase test kit
Packing specification:
20 tests/box; Quality control product: 2×1.5mL (optional)
Intended use:
This kits uses immunofluorescence double antibody sandwich assay to quantitatively detect the content of Myeloperoxidase (MPO) in human serum, plasma or whole blood.
Major components:
1 reagent strip per aluminum bag for one person test use, 1 piece of ID card, quality control products.
Storage conditions and expiration period:
The reagent should be stored at 4~30℃ and is valid for 18 months. After the aluminum bag of the test reagent is opened, it is effective within 2 hours. It is recommended to use it within 1 hour.
Quality control products should be stored at 2~8℃ and is valid for 18 months. After uncap the bottle, it is recommended to use up within 1 month.
Applicable instrument:
iRaTe 300, iRaTe 1600 dry fluorescence immunoassay analyzer from Aucheer.
Lp-PLA2 FIA
Lp-PLA2 FIA
Product name:
Lipoprotein phospholipase A2 test kit
Packing specification:
20 tests/box; Quality control product: 2×1.5mL (optional)
Intended use:
This kits uses immunofluorescence double antibody sandwich assay to quantitatively detect the content of Lipoprotein phospholipase A2 (Lp-PLA2) in human serum, plasma or whole blood.
Major components:
1 reagent strip per aluminum bag for one person test use, 1 piece of ID card, quality control products.
Storage conditions and expiration period:
The reagent should be stored at 4~30℃ and is valid for 18 months. After the aluminum bag of the test reagent is opened, it is effective within 2 hours. It is recommended to use it within 1 hour.
Quality control products should be stored at 2~8℃ and is valid for 18 months. After uncap the bottle, it is recommended to use up within 1 month.
Applicable instrument:
iRaTe 300, iRaTe 1600 dry fluorescence immunoassay analyzer from Aucheer.
IL-6 FIA
IL-6 FIA
Product name:
Interleukin-6 test kit
Packing specification:
20 tests/box; Quality control product: 2×1.5mL (optional)
Intended use:
This kits uses immunofluorescence double antibody sandwich assay to quantitatively detect the content of Interleukin-6 (IL-6) in human serum, plasma or whole blood.
Major components:
1 reagent strip per aluminum bag for one person test use, 1 piece of ID card, quality control products.
Storage conditions and expiration period:
The reagent should be stored at 4~30℃ and is valid for 18 months. After the aluminum bag of the test reagent is opened, it is effective within 2 hours. It is recommended to use it within 1 hour.
Quality control products should be stored at 2~8℃ and is valid for 18 months. After uncap the bottle, it is recommended to use up within 1 month.
Applicable instrument:
iRaTe 300, iRaTe 1600 dry fluorescence immunoassay analyzer from Aucheer.
Hs-cTnI FIA
Hs-cTnI FIA
Product name:
Hypersensitive cardiac troponin I test kit
Packing specification:
20 tests/box; Quality control product: 2×1.5mL (optional)
Intended use:
This kits uses immunofluorescence double antibody sandwich assay to quantitatively detect the content of hypersensitive cardiac troponin I (hs-cTnI) in human serum, plasma or whole blood.
Major components:
1 reagent strip per aluminum bag for one person test use, 1 piece of ID card, quality control products.
Storage conditions and expiration period:
The reagent should be stored at 4~30℃ and is valid for 18 months. After the aluminum bag of the test reagent is opened, it is effective within 2 hours. It is recommended to use it within 1 hour.
Quality control products should be stored at 2~8℃ and is valid for 18 months. After uncap the bottle, it is recommended to use up within 1 month.
Applicable instrument:
iRaTe 300, iRaTe 1600 dry fluorescence immunoassay analyzer from Aucheer.
CLA Reagent
β-HCG CLIA
β-HCG CLIA
VEGF CLIA
VEGF CLIA
Product name:
Vascular endothelial growth factor test kit (CLIA)
Packing specification:
50 tests/box; 100 tests/box;Calibrator product: 2×1.0mL; Quality control product: 2×1.0mL
Intended use:
To quantitatively detect the concentration of Vascular endothelial growth factor in human serum in vitro.
25-OH VD CLIA
25-OH VD CLIA
Product name:
25-OH Vitamin D test kit (CLIA)
Packing specification:
50 tests/box; 100 tests/box;Calibrator product: 2×1.0mL; Quality control product: 2×1.0mL
Intended use:
To quantitatively detect the concentration of 25-OH Vitamin D in human serum in vitro.
Major components:
Reagent 1, Reagent 3, Reagent 4, Reagent 5, quality control products, calibrator, ID card, control card, calibrator card ( for Shine i1910 use only).
Storage conditions and expiration period:
The detection reagent is stored at 2~8℃ and is valid for 12 months. After opening, the reagent can be stable for 45 days at 2~8℃, and it can be stable for 28 days when placed on the analyzer.
Calibration products, quality control products stored at 2~8℃, valid for 12 months, after remelting, 2~8℃ can be stable for 8 hours, -20 (±5) ℃ can be stable for 30 days.
Regarding transportation of kits, calibrators and quality control products at 2~37℃ for 7 days has no effect on product performance, and it is recommended to transport at 2~8℃
Applicable instrument:
iMAGIN 1800, Shine i1910 chemiluminescence immunoassay analyzer from Aucheer.
VB12 CLIA
VB12 CLIA
Product name:
Vitamin B12 test kit (CLIA)
Packing specification:
50 tests/box; 100 tests/box;Calibrator product: 2×1.0mL; Quality control product: 2×1.0mL
Intended use:
To quantitatively detect the concentration of Vitamin B12 in human serum in vitro.
Major components:
Reagent 1, Reagent 3, Reagent 4, quality control products, calibrator, ID card, control card, calibrator card ( for Shine i1910 use only).
Storage conditions and expiration period:
The detection reagent is stored at 2~8℃ and is valid for 12 months. After opening, the reagent can be stable for 45 days at 2~8℃, and it can be stable for 28 days when placed on the analyzer.
Calibration products, quality control products stored at 2~8℃, valid for 12 months, after remelting, 2~8℃ can be stable for 8 hours, -20 (±5) ℃ can be stable for 30 days. Do not freeze and thaw repeatedly, only freeze and thaw once.
Applicable instrument:
iMAGIN 1800, Shine i1910 chemiluminescence immunoassay analyzer from Aucheer.
uE3 CLIA
uE3 CLIA
Product name:
Uncojugated estriol test kit (CLIA)
Packing specification:
50 tests/box; 100 tests/box;Calibrator product: 2×1.0mL; Quality control product: 2×1.0mL
Intended use:
To quantitatively detect the concentration of Uncojugated estriol in human serum in vitro.
Major components:
Reagent 1, Reagent 3, Reagent 4, quality control products, calibrator, ID card, control card, calibrator card ( for Shine i1910 use only).
Storage conditions and expiration period:
The detection reagent is stored at 2~8℃ and is valid for 12 months. After opening, the reagent can be stable for 45 days at 2~8℃, and it can be stable for 28 days when placed on the analyzer.
Calibration products, quality control products stored at 2~8℃, valid for 12 months, after remelting, 2~8℃ can be stable for 8 hours, -20 (±5) ℃ can be stable for 30 days. Do not freeze and thaw repeatedly, only freeze and thaw once.
Applicable instrument:
iMAGIN 1800, Shine i1910 chemiluminescence immunoassay analyzer from Aucheer.
sFlt-1 CLIA
sFlt-1 CLIA
Product name:
Soluble fms-like tyrosine kinase-1 test kit (CLIA)
Packing specification:
50 tests/box; 100 tests/box;Calibrator product: 2×1.0mL; Quality control product: 2×1.0mL
Intended use:
To quantitatively detect the concentration of Soluble fms-like tyrosine kinase-1 in human serum in vitro.
Major components:
Reagent 1, Reagent 3, Reagent 4, quality control products, calibrator, ID card, control card, calibrator card ( for Shine i1910 use only).
Storage conditions and expiration period:
The detection reagent is stored at 2~8℃ and is valid for 12 months. After opening, the reagent can be stable for 45 days at 2~8℃, and it can be stable for 28 days when placed on the analyzer.
Calibration products, quality control products stored at 2~8℃, valid for 12 months, after remelting, 2~8℃ can be stable for 8 hours, -20 (±5) ℃ can be stable for 30 days. Do not freeze and thaw repeatedly, only freeze and thaw once.
Applicable instrument:
iMAGIN 1800, Shine i1910 chemiluminescence immunoassay analyzer from Aucheer.
PTH CLIA
PTH CLIA
Product name:
Parathyroid Hormone test kit (CLIA)
Packing specification:
50 tests/box; 100 tests/box;Calibrator product: 2×1.0mL; Quality control product: 2×1.0mL
Intended use:
To quantitatively detect the concentration of Parathyroid Hormone in human serum in vitro.
Major components:
Reagent 1, Reagent 3, Reagent 4, quality control products, calibrator, ID card, control card, calibrator card ( for Shine i1910 use only).
Storage conditions and expiration period:
The detection reagent is stored at 2~8℃ and is valid for 12 months. After opening, the reagent can be stable for 45 days at 2~8℃, and it can be stable for 28 days when placed on the analyzer.
Calibration products, quality control products stored at 2~8℃, valid for 12 months, after remelting, 2~8℃ can be stable for 8 hours, -20 (±5) ℃ can be stable for 30 days. Do not freeze and thaw repeatedly, only freeze and thaw once.
Applicable instrument:
iMAGIN 1800, Shine i1910 chemiluminescence immunoassay analyzer from Aucheer.
PPAP-A CLIA
PPAP-A CLIA
Product name:
Pregnancy-associated plasma protein A test kit (CLIA)
Packing specification:
50 tests/box; 100 tests/box;Calibrator product: 2×1.0mL; Quality control product: 2×1.0mL
Intended use:
To quantitatively detect the concentration of Pregnancy-associated plasma protein A in human serum in vitro.
Major components:
Reagent 1, Reagent 3, Reagent 4, quality control products, calibrator, ID card, control card, calibrator card ( for Shine i1910 use only).
Storage conditions and expiration period:
The detection reagent is stored at 2~8℃ and is valid for 12 months. After opening, the reagent can be stable for 45 days at 2~8℃, and it can be stable for 28 days when placed on the analyzer.
Calibration products, quality control products stored at 2~8℃, valid for 12 months, after remelting, 2~8℃ can be stable for 8 hours, -20 (±5) ℃ can be stable for 30 days. Do not freeze and thaw repeatedly, only freeze and thaw once.
Applicable instrument:
iMAGIN 1800, Shine i1910 chemiluminescence immunoassay analyzer from Aucheer.
About Us
Aucheer Bio
Aucheer Medical
Contact:86-574-87732259
Technical Support:400-008-6588
Business Mailbox:info1@aucheer.net
HR Mailbox :hr@aucheer.net
Address: North Building B, No. 885, Chunhua Rd., Wangchun Industrial Zone, Haishu District, Ningbo, Zhejiang Province, China
Aucheer Bio
Aucheer Medical
© 2021 Ningbo Aucheer Biotechnology Co., Ltd | 浙ICP备17032133号-2 | Powered by www.300.cn